Pile‐under
footing (pile‐cap) Quantity Survey | Volume Of Concrete | Area Of Shuttering |
Area Of Bitumen Paint
1. Pile‐under footing (pile‐cap) Volume Of Concrete
Calculation
2. Pile‐under footing (pile‐cap) Area Of Shuttering Calculation
3. Pile‐under footing (pile‐cap) Area Of Bitumen Paint Calculation
Pile
Dimension:
Ø = 0.50m
height = 3.5m
Solution:
1. Volume
of Concrete = Area x Depth
= π/4 x d2 x D
= π/4 x 0.52 x
3.5
=
0.687 m3
2. Shuttering
Area = Peripheral Length x Depth
= 2 x π x r x D
= 2 x π x 0.25 x 3.50
=
5.49 m2
3. Bitumen
paint Area = peripheral length x Depth + bottom area
= 2 x π x r x D + π/4 x d2
= 2 x π x 0.25 x 3.50 + π/4
x 0.52
=
5.68 m2