General Rules For Lapping In Column Reinforcement - LCETED - LCETED - LCETED Institute for Civil Engineers

Post Top Ad

May 28, 2021

General Rules For Lapping In Column Reinforcement - LCETED

General Rules For Lapping In Column Reinforcement - LCETED


In this the article, we will explain about general rules used while calculating lapping reinforcement bars.


LAP LENGTH DIAMETER

Lapping In Column


If you extend the top bar of a column from a lower (bottom) bar of unequal diameter, the lap length is calculated for the smaller diameter bar.

 

Example Calculation:

If the Top bar of 12mm dia. Is lapped with a lower (bottom) bar of 16mm dia and if the lap length is taken as 50d, then

Lap length 50d = 50 × 12mm = 600mm.  Correct

Lap length 50d = 50 × 16mm = 800mm  Incorrect

 

LAPPING ZONE

LAPPING ZONE


When we provide lapping in a column, all reinforcements must overlap in zone B-Zone as shown in the drawing. Therefore, the upper and lower part of the column should be avoided in A-Zone (length L / 4) as there will be a maximum moment in this area due to the lateral forces acting on the post.

 

LAPPING ZONE

 

If the length of the column is L, then the length L / 4 from the top and bottom of the column is classified as tension  A-zone and the central length L / 2 of the column (B-Zone) is considered a safe area for the purpose of lapping. 


ALSO READ: HOW MANY NUMBERS OF RODS PER BUNDLE? HOW TO CALCULATE IT

 

STAGGERED BAR

 

STAGGERED BAR



All bars that are overlapped should be offset in B-zone as shown in the drawing above. In any case, no more than 50% of the rebar should be lapped to the same level. If all bars in the column are overlapped at the same level, it will cause column failure.

 

 

STIRRUP SPACING

STIRRUP SPACING

 

 

The spacing of the stirrups in the zone of lapping should be minimal compared to the regular spacing of the stirrups in the c/c column.

 

If the regular spacing designed for the column stirrups is 175 c/c, then the spacing of the stirrups in the zone of lapping can be 150 c/c or 125 c/c depending on the column design.

 

 

WELDING THE REBAR

WELDING THE REBAR

 

According to the IS code, if the bar diameter is 36mm or greater, you should consider (welding) soldering these bars instead of lapping. If welding is not possible, you can overlap these bars with an additional 6mm bar spiral at the splice length.

 

 

JOGGLE LENGTH

JOGGLE LENGTH

For rebar larger than 12mm in diameter, you may consider providing a 1 in 6 joggle. This means if the bar dia. is 16 mm, then the length of the jogged part of the bar can be calculated as

 

J = 6 ×Diameter of rebar

 

= 6 × 16 mm = 96mm.

 

 

REBAR PLACING

 

REBAR PLACING

 

When we tie the reinforcement in the lapping area, the joggled part of the bar must be placed on the inner surface of the lower bar (as shown in the picture) to get an even transparent coating from the concrete surface.

If you anchor the joggled portion of rebar to the outer surface of the bottom rebar, the lapping area will invade the concrete coverage area provided for the rebars.


If you find 


This information helpful please share it.


Thanks! For reading the article.


ALSO READ: What is Lap Length | Lap length of Beams | Lap Length of Slabs | Lap Length of Columns | Lap Length Formulas



 


14 comments:

  1. thanks for sharing this plastic bord .i am prelly much pleased with your.yor put the moment is vare nais .your thsi about arlly blog comment such.comments pic

    ReplyDelete
  2. Either you are iPhone lover or android smartphone geek, you are encouraged to download SH. watch

    ReplyDelete
  3. Anonymous02 June, 2023

    Do you know? BIM Prefabrication And Fabrication Services can help a lot in creating accurate 3D rebar models. This help greatly in rebar cost estimation and placement.

    ReplyDelete
  4. Anonymous05 July, 2023

    Hi, As you have mentioned that when Column reinforcement dia is 16 mm we can provide joggle. I want to know that if there is any codal reference for that, if yes please share the same it will be helpful.

    Thanks

    ReplyDelete
  5. Anonymous27 July, 2023

    Very nyc information about Assam Government Jobs check out more details NorthEastJob.in

    ReplyDelete
  6. Nice website and very informative

    ReplyDelete
  7. Hii.. Thankyou For Sharing Inforation

    ReplyDelete
  8. Looking for CAD services in the UK? Get top-notch Legionella Risk Assessment Drawings and Legionella Compliance Drawings from our expert team.
    for more visit on: https://quantumkurv.com/legionella-schematic-drawing/

    ReplyDelete
  9. Very Informative.
    For Job related Updates
    Please Visit:
    sarkari naukri

    ReplyDelete
  10. I wanted to take a moment to express my sincere appreciation for the time I spent reading your post

    ReplyDelete
  11. Very useful information about engineering professionals, more jobs in northeast region of India.
    Please Visit: Northeastjobs

    ReplyDelete
  12. Assam Students are very innovative civil engineers, Please check for assam career jobs: Assam Career

    ReplyDelete

LCETED - "WHATSAPP GROUP"

For Instant updates Join our Whatsapp Group. Save our Whatsapp contact +919840140396 as LCETED and Send us a message “JOIN”

Post Bottom Ad